KWh meter as a measurement of electrical energy as well a means of transaction between the provider of electrical services company, PT PLN (Persero) with the consumer must have a good level of measurement accuracy, so that no party is harmed as a result of an error in the measurement process. Results of tests performed on kWh consumption meters at 5 months of age up to 12 years in mind that the average percentage measurement error at 0.5 kWh meter class brand EDMI serial number 204 042 746 service life of 12 years = -1.848%, the life span of the serial number 208 207 068 8 years = -0.977%, serial number 210 393 519 service life of 6 years = 0,929%, the life span of the serial number 215 457 334 5 months = -0.474%. while the percentage measurement error at 0.5 kWh meter class brand ACTARIS serial number 35,010,661 lifetime of 12 years = -1.434%, the serial number 36,013,208 lifetime of 11 years = -1.192%, the serial number 35,010,652 operating life of 10 years = 1,123%, the serial number 53095058 service life of 6 years = -1.003%. It can be concluded that the older and the longer life of the kWh meter then its measurement values are getting away with the real power value.